Anyone can buy a wallbox, but not everyone may connect it. Under Art. 16 NIV laypeople may carry out only narrowly defined work themselves, and a fine of up to CHF 100,000 threatens anyone who goes further. What the list contains, who else may install without a permit, and what a firm says to a customer who wants to fit the wallbox himself.


Anyone can buy a wallbox, but not everyone may connect it. Whoever creates, changes or repairs an electrical installation, or connects installations permanently, needs an installation permit from the ESTI as a rule. Laypeople may carry out only a short, precisely defined list of work themselves, and a wallbox is not on it. Anyone who installs more commits an offence.

That is the answer an electrical firm gives a customer who says: «I already have the box, I'll do the connection myself.» The sections below say what it rests on — and where the line stays blurred.

The rule

An installation permit is the ESTI's permission to create, change or repair low-voltage electrical installations. In its bulletin 6/2018 the ESTI writes that whoever does this work, or connects installations permanently, needs one (Art. 6 NIV). Electrical material, by contrast, «may be freely acquired by anyone» — sockets, switches, cables. Buying is free; fitting is not.

Under Art. 16 para. 1 NIV the following may install without a permit:

  • competent persons under Art. 8 NIV,
  • persons authorised to inspect under Art. 27 NIV,
  • qualified electricians holding the federal certificate (EFZ) —

the last group only in dwellings and their ancillary rooms that they live in themselves or own. A customer who is a qualified electrician may therefore work in his own home, but not in his parents' flat or in an apartment block.

What laypeople may do themselves

A layperson is someone who does not meet the conditions for an installation permit. Since the NIV revision of 1 January 2018, Art. 16 para. 2 let. a NIV allows them «only» the following:

  • individual sockets and switches in existing installations,
  • in the dwellings they occupy and their ancillary rooms,
  • downstream of an overcurrent breaker, on single-phase final circuits with a residual-current device of at most 30 mA.

Art. 16 para. 2 let. b adds that light fittings and the matching switches may be mounted and removed in rooms they live in — lamp holders, for example.

A wallbox does not appear in this list. The ESTI's bulletin says nothing about wallboxes; it does not say whether a single-phase box on an existing, RCD-protected circuit falls under the third line. To judge that for a customer, ask the inspection body or the ESTI instead of guessing. The rule of thumb stays: a wallbox is a new, permanently connected load, and for that the bulletin names no exception for laypeople.

What a wallbox triggers besides

Even a licensed firm is not finished once the box is connected. EV charging infrastructure is on the list of notifiable work in ESTI directive 221; how the installation notice works is in the article Installation notice: which work must be reported to the grid operator. The grid operator decides whether the wallbox may be connected, and the safety report follows the work. A layperson who fits it without a permit triggers none of this — and the grid operator ends up with an installation on its network that it knows nothing about.

What is at stake

The ESTI names two consequences:

  • Penalty. Anyone who carries out installation work beyond the scope of Art. 16 para. 2 commits an offence; if the act is intentional, the fine can be up to CHF 100,000 (Art. 55 paras. 1 and 3 of the Electricity Act).
  • Liability. The owner remains responsible for his installations meeting the safety requirements (Art. 5 para. 1 NIV). If an electrical accident is caused by a faulty installation, the owner of a building is liable for damage from a defect in construction or poor maintenance (Art. 58 para. 1 CO) — even if laypeople did the work.

Even what laypeople may do is not left to self-checking: work under Art. 16 para. 2 let. a NIV must be inspected by the holder of an inspection permit, and the inspector hands the safety report to the owner (Art. 16 para. 3 NIV). The ESTI adds that the inspection should take place as soon as possible. For let. b — light fittings and switches in rooms one lives in — no inspection is required.

What the firm tells the customer

One sentence to hand to a customer:

You can buy the wallbox yourself. Only a firm with an installation permit may connect it — we create the circuit, report the work to the grid operator and give you the safety report.

It belongs in the quote, so the question does not come up for the first time on site: whether the firm or the customer supplies the box, who guarantees it, who reports the connection. How a quote is built is in the article Writing a quote as an electrician; how the firm keeps customer, building and order together is shown by the page Customers and buildings.

If the wallbox is in a multi-unit building, the question of consent comes before the installation — in condominium ownership as decision and notification, in a rented flat as the landlord's consent.

Common questions

May I install my wallbox myself? Not without a permit, unless you are a qualified electrician (EFZ) yourself and the box goes into your own home. Laypeople may replace only individual sockets and switches in existing installations, plus light fittings (Art. 16 NIV); a wallbox is not on that list.

What happens if I do it anyway? You commit an offence; if intentional, the fine can be up to CHF 100,000. As the owner you are also liable for damage from a faulty installation.

May I buy the wallbox myself? Yes. Electrical material may be freely acquired by anyone; the permit requirement concerns fitting, not buying.

Who reports the wallbox to the grid operator? The installation notice is filed by the firm holding an installation permit; it is the permit holder's duty, not the customer's.


Sources: Peter Rey, Daniel Otti (ESTI), «Verkauf von Elektromaterial und Laieninstallationen», bulletin.ch 6/2018, pp. 2–3, esti.admin.ch. The bulletin dates from 2018; the current wording of the Low-Voltage Installations Ordinance (NIV, SR 734.27), Arts. 5, 6, 16, on fedlex.admin.ch governs. This article is not legal advice.